Riv Performance
Would you like to react to this message? Create an account in a few clicks or log in to continue.

The 8th Gen Riviera Resource
 
HomeDashboardLatest imagesSearchRiviera Questions & AnswersWrite-Ups IndexRegisterRelated LinksLog in

 

 Write-Up: Replacing Belt Tensioner Pulley (Series I)

Go down 
+9
al_roethlisberger
perbe
albertj
vendetta
Karma
1998 Riv
deekster_caddy
Rickw
cragmor
13 posters
Go to page : Previous  1, 2, 3
AuthorMessage
al_roethlisberger
Junkie
al_roethlisberger


Name : Al Roethlisberger
Age : 55
Location : Sanford, NC
Joined : 2013-03-12
Post Count : 960
Merit : 24

series i belt. - Write-Up: Replacing Belt Tensioner Pulley (Series I) - Page 3 Empty
PostSubject: Re: Write-Up: Replacing Belt Tensioner Pulley (Series I)   series i belt. - Write-Up: Replacing Belt Tensioner Pulley (Series I) - Page 3 EmptyThu Mar 13, 2014 4:16 pm

Abaddon wrote:
As long as it's tight, and you don't reef it down like Hercules, I don't see why it matters what the exact spec is. It's not like you're installing Intake or Head bolts.... smoke 

Understood, but I don't want it to be too loose and back out or allow any off-axis wobble. Also of course don't want to overtighten and strip something, or in my past experience bind one of the pulleys.

...just don't want to revisit this repair a few months down the line just because it was over/under tightened. So I was just checking.

Thanks,
Al
Back to top Go down
al_roethlisberger
Junkie
al_roethlisberger


Name : Al Roethlisberger
Age : 55
Location : Sanford, NC
Joined : 2013-03-12
Post Count : 960
Merit : 24

series i belt. - Write-Up: Replacing Belt Tensioner Pulley (Series I) - Page 3 Empty
PostSubject: Re: Write-Up: Replacing Belt Tensioner Pulley (Series I)   series i belt. - Write-Up: Replacing Belt Tensioner Pulley (Series I) - Page 3 EmptySun Mar 23, 2014 10:00 pm


OK, replaced the tensioners, idlers and installed the new "HD" Gates belts today. Pretty straightforward.

The two tensioners are indeed held on with bolts through the center from the front (1/2" bolts), so you can remove and install them individually without removing the bracket that all of these accessories mount to. The lower tensioner is a bit a trick to unmount unless you remove its pulley as its bolt is directly facing the frame so any ratchet is a tight fit.

I torqued them to ~35 ft/lb (service manual indicated 37).

I torqued the stacked idler bolt to 15 ft/lb although there is no spec I could find for the Buick, but around 14-15 seems the norm on other manufacturers. That felt "tight". If someone has a better known correct value for the stacked idlers bolt torque, that would be great to know.

One of the Pontiac guys has a write up that seems to confirm the 37 ft/lb for mounting the tensioners, but also says 37 for the idler bolt. That seems high to me for the Series I stacked idlers, but.... not sure.

http://www.paulstravelpictures.com/GM-Pontiac-Grand-Prix-Idler-and-Tensioner-Pulley-Replacement-Guide/

Back to top Go down
llamalor2112
Junkie
llamalor2112


Name : Evan
Age : 31
Location : Granite Falls, WA
Joined : 2012-07-13
Post Count : 852
Merit : 13

series i belt. - Write-Up: Replacing Belt Tensioner Pulley (Series I) - Page 3 Empty
PostSubject: Re: Write-Up: Replacing Belt Tensioner Pulley (Series I)   series i belt. - Write-Up: Replacing Belt Tensioner Pulley (Series I) - Page 3 EmptyTue Apr 08, 2014 4:43 am

Al, I haven't been able to track down any solid numbers for the idler pulleys as far as torque specs. I'll be doing mine either tomorrow or Wednesday. Will keep looking but if no luck I'll try 15ft lbs like you did as that's what I've seen most often.
I was curious though about the specs on the tensioners. You indicate 37ft lbs? Is that the assembly or the pulley? Couldn't be the pulley could it?
Back to top Go down
al_roethlisberger
Junkie
al_roethlisberger


Name : Al Roethlisberger
Age : 55
Location : Sanford, NC
Joined : 2013-03-12
Post Count : 960
Merit : 24

series i belt. - Write-Up: Replacing Belt Tensioner Pulley (Series I) - Page 3 Empty
PostSubject: Re: Write-Up: Replacing Belt Tensioner Pulley (Series I)   series i belt. - Write-Up: Replacing Belt Tensioner Pulley (Series I) - Page 3 EmptyTue Apr 08, 2014 2:19 pm

llamalor2112 wrote:
Al, I haven't been able to track down any solid numbers for the idler pulleys as far as torque specs. I'll be doing mine either tomorrow or Wednesday. Will keep looking but if no luck I'll try 15ft lbs like you did as that's what I've seen most often.
I was curious though about the specs on the tensioners. You indicate 37ft lbs? Is that the assembly or the pulley? Couldn't be the pulley could it?

 
The FSM says something "tensioner mounting bolt" = 37 ft/lbs

Along with that, I've noticed that if one tightens the "pulley bolt" more than around 15 ft/lbs, the bearings get loaded and the pulley will start to drag, esp on the tensioners, causing it to jump. So I dunno.
 
I am going by the dealer today or tomorrow and will ask them if they are willing to look up the actual pulley mount bolts, both tensioner and idler.
Back to top Go down
llamalor2112
Junkie
llamalor2112


Name : Evan
Age : 31
Location : Granite Falls, WA
Joined : 2012-07-13
Post Count : 852
Merit : 13

series i belt. - Write-Up: Replacing Belt Tensioner Pulley (Series I) - Page 3 Empty
PostSubject: Re: Write-Up: Replacing Belt Tensioner Pulley (Series I)   series i belt. - Write-Up: Replacing Belt Tensioner Pulley (Series I) - Page 3 EmptyWed Apr 09, 2014 4:33 pm

This is series 2 info....

Belt idler pulley bracket bolt 22 ft/lbs
Belt Idler Pulley Bolt (VIN 1) 37 ft/lbs
Drive Belt Tensioner Bolt 37 ft/lbs
Drive Belt Tensioner Bracket Bolt (VIN 1) 37 ft/lbs

BUT you say that the idlers start to bind past 15 ft/lbs....

Robo or the dynamic Dave duo have any info on this?
Back to top Go down
deekster_caddy
Master



Name : Derek
Age : 52
Location : Reading, MA
Joined : 2007-01-31
Post Count : 7717
Merit : 109

series i belt. - Write-Up: Replacing Belt Tensioner Pulley (Series I) - Page 3 Empty
PostSubject: Re: Write-Up: Replacing Belt Tensioner Pulley (Series I)   series i belt. - Write-Up: Replacing Belt Tensioner Pulley (Series I) - Page 3 EmptyWed Apr 09, 2014 5:08 pm

The pulley bolt itself is a special bolt that mates up a shoulder with the inner bearing race. If you overtighten it, you still shouldn't be able to expand that race. Use of the incorrect bolt, however, could cause it to be tightening on the wrong spot causing binding.

IMO you don't want to overtighten it because you are threading into aluminum. But the pulley should be unaffected (unless you really really REALLLLLY overtighten)
Back to top Go down
Sponsored content





series i belt. - Write-Up: Replacing Belt Tensioner Pulley (Series I) - Page 3 Empty
PostSubject: Re: Write-Up: Replacing Belt Tensioner Pulley (Series I)   series i belt. - Write-Up: Replacing Belt Tensioner Pulley (Series I) - Page 3 Empty

Back to top Go down
 
Write-Up: Replacing Belt Tensioner Pulley (Series I)
Back to top 
Page 3 of 3Go to page : Previous  1, 2, 3
 Similar topics
-
» Write-Up: How to install an aftermarket SC pulley (Series I)
» Write-Up: Replacing Supercharger Belt Tensioner
» Accessory belt tensioner pulley
» Write-Up: Replacing Injectors (Series I)
» FAQ: Selecting Proper Supercharger Pulley & Belt Size (Series I)

Permissions in this forum:You cannot reply to topics in this forum
Riv Performance ::   Supercharged 3800 Tech :: Series I Engine & Transmission-
Jump to: